SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

SP100 Portable Spirometer with 7 Inch Colour Touch Screen, FVC SVC MVV Lung Function Testing, Thermal Printer and Over 10000 Record Storage

SP100
£793.68
Sale price  £793.68 Regular price 
Skip to product information
SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

SP100 Portable Spirometer with 7 Inch Colour Touch Screen, FVC SVC MVV Lung Function Testing, Thermal Printer and Over 10000 Record Storage

£793.68
Sale price  £793.68 Regular price 
ModelSP100

SP100 Portable Spirometer with 7 Inch Touch Screen and Thermal Printer

SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

The SP100 portable spirometer brings lung function measurement, waveform display, data storage and direct report printing together in one 1.8 kg unit. It measures Forced Vital Capacity, Vital Capacity and maximum voluntary ventilation, covering FVC, VC/SVC and MVV testing with more than 50 parameters. Its 7 inch colour TFT touch screen can be operated alongside physical buttons, while real-time Flow-Volume loops and Volume-Time curves present respiration graphically. Built-in BTPS automatic correction, calibration, multiple predicted values and lung age estimation add further testing functions. Intended settings include hospitals and clinics, as well as community, school and factory health examinations, epidemiological investigations and occupational disease screenings. A built-in lithium battery supports DC use, and the supplied power cord enables AC operation.

Lung Function Measurements and Test Displays

SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

The SP100 combines several lung function test modes with numerical and graphical results. Users can review individual parameters, compare measured values with predicted values and display the optimal result after several measurements. Test time and environmental temperature are also shown, keeping relevant session information visible alongside the testing process.

FVC SVC and MVV Parameters

FVC measurement includes FVC, FEV1, PEF, FEV1%, FEV1/FVC, FEF25, FEF50, FEF75, FEF2575, FEV1/VC, FEV6, FEV1/FEV6, ELA, FET, EVOL, FIVC, FIV1, FIV1/FIVC, PIF and MVV. VC/SVC testing covers VC, IC, ERV, IRV, EVC, IVC, TV, VE, RR, tI, tI/tE, tE, TV/tI and tI/ttot, while the MVV mode measures maximum voluntary ventilation. The FVC volume range is 0–10 L, with volume accuracy of ±3% or ±0.05 L, whichever is greater. Flow measurement spans 0–16 L/s, with accuracy of ±5% or ±0.2 L/s, whichever is greater.

Flow Volume Loops and Curves

Real-time respiration waveforms give the operator two graphical views of a test. The Flow-Volume loop presents the relationship between airflow and volume, while the Volume-Time curve charts volume against elapsed time. These displays sit alongside the numerical parameter results on the colour screen rather than requiring a separate waveform display unit. Having both chart types available within the SP100 supports review of each recorded effort as testing takes place. The screen also presents test time and environmental temperature, and the measured-to-predicted value ratio provides an additional way to show the subject’s condition using the selected predicted values.

Predicted Values and Best Results

Multiple predicted values can be selected for different populations, allowing the operator to choose an appropriate reference for the person being tested. The device can then display the ratio between the measured value and the predicted value. When a test is performed several times, the SP100 displays the optimal result, reducing the need to identify that result manually from the repeated measurements. More than 10,000 groups of data can be stored on the device for subsequent access. A lung age estimation function is also included, alongside the principal FVC, VC/SVC and MVV measurements and their associated parameters.

Touch Screen Controls and Reporting Tools

SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

Controls, visual guidance and printing are integrated into the spirometer to support the testing workflow. The display provides both touch and button operation, the animation guide assists with test use across different age groups, and the thermal printer produces reports directly without relying on a separate printer.

Seven Inch Colour TFT Display

The 7 inch colour TFT touch screen provides the main visual interface for measurements, waveform charts and test information. Physical buttons can be operated along with the touch screen, giving the user two ways to control the device. This arrangement keeps parameter readouts, Flow-Volume loops and Volume-Time curves within the same display area. Environmental temperature and test time can also be shown. The screen is built into a unit measuring 315 mm long, 215 mm wide and 92 mm high, so the display and testing electronics remain together in a single portable enclosure weighing 1.8 kg.

Incentive Guidance for Different Ages

An incentive animation operation guide is included to support use with children and older people. The guide forms part of the testing interface, providing visual direction while the operator conducts a measurement. This is particularly relevant to the stated uses in schools, community health examinations and clinics, where operators may work with people from different age groups. Touch and button controls remain available alongside the animations. The guidance is intended to make operation between children and older users easier, while the numerical results, predicted-value ratios and real-time waveform displays continue to provide the operator with the recorded test information.

Built In Thermal Report Printer

Reports can be printed directly using the built-in thermal printer, keeping result output within the SP100 itself. The specified recording paper is high-speed thermal paper measuring 112 mm wide and 20 m long, and one recording paper item is included with the device. Direct printing is useful where a physical report is required after testing in a hospital, clinic or screening setting. The printer shares the portable unit with the screen, storage and measurement functions, avoiding the need to connect a separate report printer. A USB cable is also supplied, although the source does not specify further data-transfer functions.

Power Calibration and Data Management

SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

The SP100 includes functions for environmental compensation, calibration and session record storage. Its power arrangement supports fixed and portable working, while the supplied accessories cover the stated testing, printing and connection requirements. The source also defines the electrical input and equipment safety classification.

BTPS Correction and Calibration Functions

BTPS automatic correction compensates for the impact of environmental differences during measurement. This function operates alongside the environmental temperature display, giving the device a stated method of accounting for varying test conditions. A calibration function is included to ensure measurement accuracy, and the technical specifications separately state the volume and flow accuracy tolerances. These features apply to the measurement system rather than changing the reported 0–10 L FVC volume range or 0–16 L/s flow range. Selecting suitable predicted values remains a separate step, allowing reference values to be matched to different populations before reviewing measured-to-predicted ratios.

Lithium Battery and Mains Power

A built-in lithium battery supports DC operation, while AC power is available through the supplied power cord. The stated power supply is 100–240 V at 50 Hz or 60 Hz, with an input power of 60 VA. This allows the same device to be used with mains power or its internal battery according to the working setting. Electrical safety is specified as Class I equipment with a type BF applied part. These details are provided alongside the 1.8 kg weight and compact external measurements, giving purchasers concrete information for planning use in consulting rooms, screening locations and other stated environments.

Storage Accessories and Physical Dimensions

The SP100 stores more than 10,000 groups of data and comes with four disposable mouthpieces, one nose clip, one USB cable, one recording paper item, one power cord and one user manual. The main unit measures 315 × 215 × 92 mm and weighs 1.8 kg. Its specified printing consumable is 112 mm × 20 m high-speed thermal paper. These figures describe the supplied configuration without assuming additional sensors, software, carrying cases or consumables. Together, the storage capacity, listed accessories and direct printer define a self-contained testing package for the hospital, clinic, community, school and factory applications identified by the manufacturer.

SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer
SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer
SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer
SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer
SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer
SP100 portable spirometer with 7 inch colour touch screen and built-in thermal printer

You may also like